SP-TMP36

Introduction

SP-TMP36 is a three terminal probe based on the low voltage, precision centigrade temperature sensor TMP-36 (Analog Devices). It provides a voltage output that is linearly proportional to the Celsius (centigrade) temperature with a scale factor of 10 mV/°C. SP-TMP36 does not require any external calibration to provide typical accuracies of ±1°C at +25°C and ±2°C over the −40°C to +125°C temperature range. It is intended for single-supply operation from 2.7 V to 5.5 V maximum. The supply current runs well below 50 μA, providing very low self-heating, less than 0.1°C in still air.

Features

  • Highly linear output (±0.5°C typ).
  • Wide temperature range: -40°C to +125°C.
  • Calibrated directly in °C.
  • Ultra low power: less than 50 μA quiescent current.
  • Waterproof standard version.

Ordering Codes

Code Description
SP-TMP36-SSC Temperature probe, waterproof

Specifications

Power supply
Supply voltage 2.7..5.5 VDC
Supply current 50 μA max
Accuracy
Calibration error 1° @ 25°C typ
Nonlinearity 0.5° typ
Output characteristics
Temperature range −40°C to +125°C
Nominal output voltage 750 mV @ 25°C
Output voltage range 100…2000 mV
Temperature coefficient 10mV/°C
Other
Cable length 1.2 m
Document File
TMP36, Voltage type temperature sensor  TMP36_V1pdf